Associated content: 

Millimeter Imaging Radiometer

The Millimeter-wave Imaging Radiometer (MIR) is a cross-track-scanning radiometer that measures radiation at nine frequencies. In every scanning cycle of about 3 seconds in duration, it views two external calibration targets. MIR responds predominantly to atmospheric parameters like water vapor, clouds, and precipitation.

Instrument Type: 
Measurements: 
Point(s) of Contact: 

MODIS/ASTER Airborne Simulator

The MASTER is similar to the MAS, with the thermal bands modified to more closely match the NASA EOS ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer) satellite instrument, which was launched in 1998. It is intended primarily to study geologic and other Earth surface properties. Flying on both high and low altitude aircraft, the MASTER has been operational since early 1998.

Instrument Type: Multispectral Imager
Measurements: VNIR/SWIR/MWIR/LWIR Imagery

Instrument Type: 
Measurements: 
Point(s) of Contact: 

Multichannel Coherent Radar Depth Sounder

The Center for Remote Sensing of Ice Sheets (CReSIS) has developed radars (MCoRDS) that operate over the frequency range from 140 to 230 MHz with multiple receivers developed for airborne sounding and imaging of ice sheets. MCoRDS radars have an adjustable radar bandwidth of 20 MHz to 60 MHz. Multiple receivers permit digital beamsteering for suppressing cross-track surface clutter that can mask weak ice-bed echoes and strip-map synthetic aperture radar (SAR) images of the ice-bed interface. With 200 W of peak transmit power, a loop sensitivity > 190 dB is achieved. These radars are flown on twin engine and long-range aircraft including NASA P-3 and DC-8.

Instrument Type: 
Measurements: 
Point(s) of Contact: 

Multi-kilohertz Microlaser Altimeter

Developed by Dr. John Degnan under the Instrument Incubator Program, the MMLA is designed to detect single photon returns reflected from targets of interest and determine their height. This instrument is comprised of an optical bench, transmit and receive optics, computer-controlled iris, spatial and spectral filters, stray-light baffles, interface optics to a micro-laser transmitter, photo detector, and CCD camera.

Instrument Type: 
Measurements: 
Aircraft: 
Point(s) of Contact: 

MACRES Ground Receiving Station (MGRS)

Aircraft: 
Point(s) of Contact: 

Marshall Airborne Polarimetric Imaging Radiometer

The Marshall Airborne Polarimetric Imaging Radiometer (MAPIR) is a dual beam, dual angle polarimetric, scanning L band passive microwave radiometer system developed by the Observing Microwave Emissions for Geophysical Applications (OMEGA) team at MSFC. MAPIR observes naturally-emitted radiation from the ground primarily for remote sensing of land surface brightness temperature from which we can retrieve soil moisture and possibly surface or water temperature and ocean salinity.

MAPIR consists of an electronically steered phased array antenna comprised of 81 receiving patch elements and associated electronics to provide the required beam steering capability. The antenna produces two independent beams that can be individually scanned to any user-defined scan angle. The antenna is connected to four microwave radiometers and a microwave spectrum analyzer. Two radiometers operate over a narrow band (science band) between 1400-1427 MHz. Two other radiometers operate over a wider bandwidth (1350-1450 MHz) and are used for Radio Frequency interference (RFI) surveillance. The outputs of the four radiometers are routed to the digital back end module that digitizes and filters the signal into 16 well isolated spectral sub-bands and computes the first four statistical moments in each sub-band from which the radio brightness temperature and kurtosis (a statistical measure, indicative of RFI) can be computed in post-processing.

MAPIR can operate in two user-selectable modes: Single-Beam Dual (simultaneous) Polarization and Dual (simultaneous) Beam Single Polarization. In the first mode, both beams of the antenna are directed to scan to the same angle, but the radiometers are observing orthogonal polarizations (horizontal and vertical) at the same time. In the second mode, the two antenna beams can be directed to different azimuth and/or angles and the radiometers observe the same polarization at the same time. The instrument is capable of electronic beam steering to one-degree of resolution from 0-40 degrees in elevation and 0-360 degrees azimuth in both beams. MAPIR precision is 0.01K and brightness temperature accuracy is 5 degrees K accuracy over a 10 ms integration interval, but is capable of achieving 0.5K sensitivity over a 1 second integration interval. Near-term improvements to MAPIR will bring that accuracy to 3 K over a 10 ms integration period.

Instrument Type: 
Measurements: 
Aircraft: 
Point(s) of Contact: 

L-Band Interference Surveyor/Analyzer

LISA co-observes with existing passive microwave sensors to identify sources of damaging radio frequency interference (RFI)

· 1200-1700 MHz using broadbeam spiral antenna
· Spectrum analyzer for full bandwidth monitoring of power spectral density
· 14 MHz (8+8 bit @ 20 MSPS) coherent sampling capability for waveform capture and analysis
· Flexible script command language for system control & experiment automation

Measurements: 
Aircraft: 
Point(s) of Contact: 

Hawaii Group for Environmental Aerosol Research

1) Time of Flight Aerosol Mass Spectrometer (ToF-AMS)

Total and single particle characterization of volatile aerosol ionic and organic components (50-700nm). Uncertainty depends on species and concentration.

2) Single Particle Soot Photometer (SP2)

Single particle measure of BC (soot) mass in particles and determination of mixed particle size and non-BC coating using laser scattering and incandescence. 70-700nm. Single particle counting up to 10,000 per sec.

3) A size-resolved thermo-optic aerosol discriminator (30 s avg.):

Aerosol size distribution from 0.12 up to 7.0 μm, often where most aerosol mass, surface area and optical effects are dominant. Uses a modified Laser Optical Particle Counter (OPC) and computer controlled thermal conditioning system is used upstream (airstream dilution dried). Characterizes aerosol components volatile at 150, 300 and 400C and refractory aerosol at 400C (sea salt, dust and soot/flyash). (Clarke, 1991, Clarke et al., 2004). Uncertianty about 15%

4) Condensation Nuclei - heated and unheated (available at 1Hz)

Two butanol based condensation nuclei (CN) counter (TSI 3010) count all particles between 0.01-3.0 um. Total CN, refractory CN (those remaining at 300C after sulfate is removed) and volatile CN (by difference) are obtained as a continuous readout as a fundamental air mass indicator (Clarke et al. 1996). Uncertainty ~ 5%.

5) Aerodynamic Particle Sizer – (APS-TSI3320) – (<5min/scan)

To further characterize larger “dry” particles, including dust, an APS is operated which sizes particles aerodynamically from 0.8 to 20 μm into 50 channels. Uncertainty~10%.

6) Differential Mobility Analyzer with thermal conditioning – (<3 min/scan)

Volatility tandem thermal differential mobility analyzer (VTTDMA) with thermal analysis that provides size information (mass, surface area, number distributions) and their state of mixing over the 0.01 to 0.3μm size range (Clarke et al., 1998, 2007) for sampling times of about 1-3 minutes. Uncertainty ~10%

7) Nephelometer (10-7 m-1 detection for 60s avg., recorded every 1 sec.)

A 3 wavelength nephelometer (450, 550, 700nm) is used for total scattering and submicrometer scattering values using a Radiance Research single wavelength nephelometer (and thereby coarse dust scattering by difference).

8) Two Particle Soot Absorption Photometers (PSAP-Radiance Research; detection <0.1μg m-3 for 5 min. avg. )

The PSAP is used to quantify the spectral light absorption coefficient of the total and submicron aerosol (eg. soot, BC) at three wavelengths (450, 550, 660nm).

9) Humidity Dependent Light-Scattering (10-6 m-1 detection for 60s avg.; recorded every 1 s)

Two additional Radiance Research single-wavelength nephelometers are operated at two humidities (high/low) to establish the humidity dependence of light scattering, f(RH).

Point(s) of Contact: 

Diode Laser Hygrometer

The DLH has been successfully flown during many previous field campaigns on several aircraft, most recently ACTIVATE (Falcon); FIREX-AQ, ATom, KORUS-AQ, and SEAC4RS (DC-8); POSIDON (WB-57); CARAFE (Sherpa); CAMP2Ex and DISCOVER-AQ (P-3); and ATTREX (Global Hawk). This sensor measures water vapor (H2O(v)) via absorption by one of three strong, isolated spectral lines near 1.4 μm and is comprised of a compact laser transceiver and a sheet of high grade retroflecting road sign material to form the optical path. Optical sampling geometry is aircraft-dependent, as each DLH instrument is custom-built to conform to aircraft geometric constraints. Using differential absorption detection techniques, H2O(v) is sensed along the external path negating any potential wall or inlet effects inherent in extractive sampling techniques. A laser power normalization scheme enables the sensor to accurately measure water vapor even when flying through clouds. An algorithm calculates H2O(v) concentration based on the differential absorption signal magnitude, ambient pressure, and temperature, and spectroscopic parameters found in the literature and/or measured in the laboratory. Preliminary water vapor mixing ratio and derived relative humidities are provided in real-time to investigators.

Instrument Type: 
Measurements: 
Point(s) of Contact: 

Differential Absorption Carbon monOxide Measurement

The in‐situ diode laser spectrometer system, referred to by its historical name DACOM, includes three tunable diode lasers providing 4.7, 4.5, and 3.3 μm radiation for accessing CO, N2O, and CH4 absorption lines, respectively. The three laser beams are combined by the use of dichroic filters and are then directed through a small volume (0.3 liter) Herriott cell enclosing a 36 meter optical path. As the three coincident laser beams exit the absorption cell, they are spectrally isolated using dichroic filters and are then directed to individual detectors, one for each laser wavelength. Wavelength reference cells containing CO, CH4, and N2O are used to wavelength lock the operation of the three lasers to the appropriate absorption lines. Ambient air is continuously drawn through a Rosemount inlet probe and a permeable membrane dryer which removes water vapor before entering the Herriott cell and subsequently being exhausted via a vacuum pump to the aircraft cabin. To minimize potential spectral overlap from other atmospheric species, the Herriott cell is maintained at a reduced pressure of ~90 Torr. At 5 SLPM mass flow rate, the absorption cell volume is exchanged nominally twice per second. Frequent but short calibrations with well documented and stable reference gases are critical to achieving both high precision and accuracy. Calibration for all species is accomplished by periodically (~4 minutes) flowing calibration gas through this instrument. Measurement accuracy is closely tied to the accuracy of the reference gases obtained from NOAA/ESRL, Boulder, CO. Both CO and CH4 mixing ratios are provided in real-time to investigators aboard the DC‐8.

Measurements: 
Point(s) of Contact: 